球囊导管激光焊接设备LBS6000_英文

其他分类其他2024-09-30
102

LBS6000 catheter laser bonders combine the functionalities of LBS4000 and LBS5000 models yet provide better ergonomics and laser safety as well as additional functions such as motorized revolving safety door, advanced in-step air cooling, ball screw actuator, integrated diode pointer and beam shutter, redesigned beambender block, and multiple choice of sample holding system configurations. With LBS6000 laser bonders, customers continue to enjoy the stability and reliability of previous models. Yet experience the advanced hardware and software features process engineers keen to have.

  • 10W closed loop CO2 laser with 2% power stability. Water cooling ready
  • Programmable beam shutter eliminates power surge
  • Integrated red diode pointer and beam shutter
  • Redesigned beambender block for easy beam tuning
  • Fast lens positioning
  • Spot out of spec warning
  • Improved power calibration accuracy with non-linear modeling
  • Auto power calibration
  • Support parallel beam with beam expander and adjustable beam mask

Figure 2 Programmable Spot Beam Delivery System

Figure 4 Easy to use
 programming interface

Figure 3 Highly dynamic Window based user interface

Figure 1LBS6000 Balloon Catheter Laser Bonder

Machine Vision System

Safety and Ergonomics

Figure 5 Choices of holding chucks

  • No need to find slot position.
  • 0-1/4” opening.
  • Easy sample loading/unloading.
  • Reliable open/close actions.

Figure 6  Direct drive spindle 

Figure 7  Multi-slot segmented chuck with 0-1/4” opening

LBS6000 CATHETER LASER BONDER 

EQUIPMENT OVERVIEW

FEATURE

Laser and Beam Delivery System

Sample Holding System

  • Direct drive spindle with servo motor
  • Higher torque, quiet move, precise speed control
  • Multiple choices of spindle configurations
  • Automatic spindle recognition
  • Multiple choice of holding chucks
  • Redesigned multi-slot segmented chucks

  • HDMI video camera and cross hair generator
  • Up to 8 cross hair lines (4 horizontal and 4 vertical)
  • Easy adjustment for line positions
  • 15” or larger HD monitor

User Interface and Control System

  • 7” or larger high resolution touch screen HMI
  • Easy to use serial programming interface
  • Save up to 1000 recipes in HMI, support unlimited recipes with USB backup/restore functionalities

  • True class I safety enclosure with revolving safety door
  • Ergonomic layout of monitor and operator panel
  • Exponential joystick speed adjustment for both precise position control and high speed move

     Multi-slot segmented chuck

Laser Actuator

  • Ball screw actuator
  • 350 travel distance

LBS6000 SAMPLE HOLDING SYSTEM CONFIGURATIONS

FEATURES \\ MODELS LBS6100 LBS6200 LBS6300
10WCO2
Closed Loop Laser with 2% Stability
Real Time power Display
Electronic Shutter to eliminate power surge
Auto Power Calibration Software Module
Configurable sample holding system
Support catheter drop loading/unloading
Standard configuration: Catheter clamp + direct drive spindle
Dual direct drive spindles
optional optional optional
Multiple catheter clamps
optional optional optional
Laser Move Delivery System:Expanded Parallel  Beam  N/A N/A
Laser Move Delivery System:Manual Focused beam N/A N/A
Laser Move Delivery System:Programmable Spot with Motorized Lens                   N/A N/A
7” High Resolution Touch Screen Controller
Multi Language Support
Built-in Cross Hair Generator
Machine Vision System with built-in 15” LCD Monitor
Automatic Recipe Selection with Barcode Scanner
optional optional optional
Process and Calibration Data Reporting to PC
Powered Safety Door Open/Close
Serial Multi -Step Bonding Recipe Interface
Free Tech Support
Life Time Software Update

CONFIG #1: Spindle on the right side, clamp on the left side. Recommended to use with catheters with short to medium length balloons. Any types of chuck can be installed on the spindle. The chuck will hold the distal end of the support mandrel and rotate. Clamp will hold the proximal side of the balloon as a guide. Allow quick drop loading.

CONFIG #2: Spindle on the left side, clamp on the right side. Recommended to use with catheters with short to medium length balloons and non-circular shaft tubing. Recommend to use segmented or touhy borst chucks on the spindle. The chuck will hold the proximal side of the balloon and rotate. Clamp will hold the distal end of the support mandrel.

CONFIG #3: Spindle on the left side, dual clamps on each side of the balloon. Recommended to use with catheters with short to long length balloons and long shaft. Recommend to use the segmented or touhy borst chucks on the spindle. The chuck will hold the proximal end of the catheter. Clamps will hold both proximal and distal end of the balloon. Allow drop-in loading, efficient and precise.

CONFIG #4: Dual spindle for holding catheters with built in guide wire or without through inner lumen, or for long and large size catheters.OTHER CONFIGURATIONS: More configurations are possible, for example, by using more than two clamp for long and thicker catheters to prevent excessive wobbling.

LBS6000 LASTER BONDER FEATURE COMPARISONS

Innova Design, Inc .
Tel: (US)(001) 858-535-9389 (China) (0086) 0371-60986806 18603720011 15603712688
Web: https://innovadesigninc.com
E-mail: info@innovadesigninc.com(US) info@zbamed.com (China)
Add: 13230 Evening Creek Dr. S, Suite 216, San Diego, CA 92128, USA

Copyright © 2024 陕西妙网网络科技有限责任公司 All Rights Reserved

增值电信业务经营许可证:陕B2-20210327 | 陕ICP备13005001号 陕公网安备 61102302611033号