Ningbo Deling Electron technology company, establish in 2010, is a medium-scale enterprises specializing in producing of various kinds of satefy alarms. The company combine research, design,production and sales and have achieved several national security certificaiton such as EN54/EN14604 for environment protection and social responsibility.

The production environment strictly implements ISO-9001:2008 and all products are strictly in accordance with the relevant standards,control each production link,and constantly improve product quality and has relevant testing equipment tracking test,UL standard smoke tunnel, EN standard smoke tunnel, high and low temperature controller, gas analyzer,aging test room and other necessary equipment.

Deling products are exported to around 20 countries, its products mainly include: various kinds of sensor alarms(smoke alarms, gas alarms,carbon monoxide alarms,heat alarms), fire alarm control panel(addressable and conventional) and so on.

ontents

Company Profile

02
03
04

Company Profile
Test  Tunnel
Our factroy

Conventional Fire Alarm System

08

Addressable Fire System

Addressable Fire Alarm System

10
12
14
16
18
19

Control Panel
Some detector
Heat detector
Fire bell
Fire siren
Fire call point

Standalone Detctor

26
28

Standalone smoke detector
Gas detector

AWT Smoke Test Tunnel

Constant Temperature And Humidity Box

UL Smoke Test Tunnel

CE Smoke Test Tunnel

Our factory

Office environment &Sample room

Office environment &Sample room

NW-6300

EN-01

  • Using advanced industry-standard protocol for fast and stable communication
  • Uses standard wire, no shielded or twisted pair required on SLC loops
  • Automatic drift compensation & daily calibration
  • Field-programmable on panel
  • Powerful & versatile Cause & Effect programming (fire protection-related device control)
  • Primary Power Supply: 120V or 220VAC 50/60Hz
  • Power Supply Output: 24VDC @ 3.0 Amps (2.5 Amps available for system power)
  • 2*12V/1.2Ah batteries
  • 4.3’’ Color Display
  • Stores 999 events
  • 1 loop
  • Devices per loop: 220 sensors & modules & call points
  • Operation Temperature: –10°C~+50°C Related Humidity: ≤95% (40±2°C)
  • Dimensions (D * W * H): 80×320×240mm 
  • Weight: 3.5KgN OUTPUT WITH RELAY. 

  • It can realize electronic coding and rewrite the address via coder in situ.
  • Non-polarity, two-bus connection that ensures convenient installation and maintenance.
  • Standby current:<0.3mA
  • Alarm Current:<3 mA
  • Programming:electronically addressed Programming range:1-220
  • Wiring loop: two wire
  • Temperature:-10℃---50℃
  • Humidity : <95%
  • Operating voltage:loop 24V ( 18V---28V)
  • Sensitivity: 0.13db/m

  • Standby current : loop <0.3mA
  • Alarm Current :loop<3 Ma
  • Programming :electronically addressed
  • Programming range :1-220
  • Wiring : loop: two wire
  • Temperature :-10℃---50℃
  • Humidity :<95%
  • Operating voltage:loop 24V ( 18V---28V)
  • Temp.Trip Point: 57℃(135℉)
  • Rate of rise: 8℃(15℉)/MIN

www.nbdeling.com

Addresable Fire Alarm System

SD-604D

SD-504D

  • The Address Encoder has 2 functions including Writing Address, Reading Address.
  • The Address Encoder has 4 touch key switches and a LCD screen.
  • The keystroke includes Plus 1 key, Minus 1 key, Plus 10 key, Minus 10 key.
  • The LCD screen displays the type of functions, Address No.
  •  Power Supply is 6 voltage battery.

FIRE ALARM CONTROL PANEL 1~24 ZONES

ADDRESSABLE ENCODE 

ADDRESSABLE SMOKE DETECTOR 

ADDRESSABLE HEAT DETECTOR 

FA-410D

  • Standby Current: loop <1mA
  •  Action Current: loop<3 m A
  • Programmable electronical addressed
  •  Programming range 1~220
  • Wiringloop: two wire
  •  Power: two wire
  • Temperature: -10 ~50
  • Humidity: <95%
  •  Loop input: loop 24V ( 18V~28V)
  • Power inputpower 24V (20V~28V)
  • Power consumption: <3.2W
  • Sound level:105dB@1m

ADDRESSABL FIRE SIREN

  • Lever reusable ( non-glass break)
  • Standby current : loop <0.8mA power<2mA
  • Action Current : loop<3 Ma power<15mA
  • Programming : electronically addressed
  • Programming range:1-220
  • Indicators :inspection indicator: I blink once about every 12 seconds in the inspection status or remain lit in the output status; Input indicator: remain lit in the feedback status.
  • Wiring :loop: two wire
  • Temperature :-10℃---50℃
  • Humidity :<95%
  • Operating voltage: loop 24V ( 18V---28V)

  • Operating Voltage: DC24V
  • Standby Current:≤400uA
  • Alarm Current:≤3mA
  • Connection: Two wires,non-polarity
  • Range of Address:1~220

  • Operating Voltage: DC8V~DC30V, Two-wire bus
  • Protection Condition: Short Circuit of the Output Terminal
  • Size: 80×80×40mm (L×W×H)
  • Using Environment: Temperature:–10℃ ~+50℃
  • Related Humidity:≤95%(40±2℃)

www.nbdeling.com

Addresable Fire Alarm System

MD-103

MD-104

  • Operating Voltage: DC24V
  • Standby Current:≤400uA
  • Alarm Current:≤3mA
  • Connection: Two wires,non-polarity
  • Range of Address:1~220

ADDRESSABLE CALL POINT

ADDRESSABLE INPUT MODULE    

ADDRESSABLE SMOKE DETECTOR 

ADDRESSABLE HEAT DETECTOR 

MD-105

  • Operating Voltage: DC24V
  • Standby Current:≤5mA
  • Alarm Current:≤25mA
  • Connection: Two wires,non-polarity
  • Range of Address:1~220

ADDRESSABL FIRE SIREN

FA-511

MD-101

MD-102

ADDRESSABLE INPUT MODULE    

  • Operating Voltage: DC24V
  • Standby Current:≤400uA
  • Alarm Current:≤3mA
  • Connection: Two wires,non-polarity
  • Range of Address:1~220

NW8000

NW8100

  • Battery and energy interruption alarm
  • LED display
  • Zone power, alarm, fault led indicators
  • Manual alarm, siren and reset buttons
  • Alarm output and siren output with relay
  • AC input:110/220 VAC
  • DC output:24 VDC
  • Battery type:2 x 12 V/1.3 Ah
  • Detector connecting:20pcs (each zone)
  • End of line resister:10k
  • Alarm output: Relay
  • Siren output: Available
  • Dimension: 300x 200x 90mm

  • Battery and energy interruption alarm
  • LED display
  • Zone power, alarm, fault led indicators
  • Manual alarm, siren and reset buttons
  • Alarm output and siren output with relay
  • AC input:110/220 VAC
  • DC output:24 VDC
  • Battery type:2 x 12 V/1.3 Ah
  • Detector connecting:20pcs (each zone)
  • End of line resister:10k
  • Alarm output: Relay
  • Siren output: Available
  • Dimension: 300x 200x 90mm

  • Battery and energy interruption alarm
  • Zone power, alarm, fault led indicators
  • Manual alarm, siren and reset buttons
  • Access key
  • Alarm output and siren output with relay
  • AC input:220 VAC
  • DC output:24 VDC
  • Battery type:2 x 12 V/1.3 Ah
  • Detector connecting:20pcs (each zone)
  • End of line resister:10K
  • Alarm output: Relay
  • Siren output: Available
  • Display: Led
  • Dimension: 300x 200x 90mm

www.nbdeling.com

Conventional Fire Alarm System

NW8200

NW8300

FIRE ALARM CONTROL PANEL 1~24 ZONES

FIRE ALARM CONTROL PANEL 1~24 ZONES

FIRE ALARM CONTROL PANEL 1/2/4 ZONES

FIRE ALARM CONTROL PANEL 8/16/32 ZONES

  • Battery and energy interruption alarm
  • Zone power, alarm, fault led indicators
  • Manual alarm, siren and reset buttons
  • Access key
  • Alarm output and siren output with relay
  • AC input:220 VAC
  • DC output:24 VDC
  • Battery type:2 x 12 V/1.3 Ah
  • Detector connecting:20pcs (each zone)
  • End of line resister:10K
  • Alarm output: Relay
  • Siren output: Available
  • Display: Led
  • Dimension: 300x 200x 90mm

  • Low standby current,Anti-RFI& anti-EMI
  • Operating voltage:DC:9V~35V(orders:DC40~60V)
  • Flashing led power indicator
  • Standby current 55uA
  • Alarm indication: red LED
  • Alarm current: 55mA@DC24V;25mA@DC12V
  • Reset: power off or auto reset
  • Alarm output: Remote led for 2 wires;Relay output for 4 wires
  • Sensitivity 0.13db/m( 0.05db/m)
  • Standard ED54-7 UL268
  • Dimension D103mm.*H53mm

  • Low standby current,Anti-RFI& anti-EMI
  • Operating voltage:DC:9V~35V(orders:DC40~60V)
  • Flashing led power indicator
  • Standby current 55uA
  • Alarm indication: red LED
  • Alarm current: 55mA@DC24V;25mA@DC12V
  • Reset: power off or auto reset
  • Alarm output: Remote led for 2 wires;Relay output for 4 wires
  • Sensitivity 0.13db/m( 0.05db/m)
  • Standard ED54-7 UL268
  • Dimension D101mm.*H49mm

  • Low standby current, Anti-RFI& anti-EMI
  • Operating voltage:DC:9V~35V(order:DC40~60V)
  • Flashing led power indicator
  • Alarm indication: red LED
  • Standby current 55uA
  • Alarm current: 55mA@DC24V;25mA@DC12V
  • Reset: power off or auto reset
  • Alarm output: Remote led for 2 wires;Relay output for 4 wires
  • Sensitivity 0.13db/m( 0.05db/m)
  • Standard ED54-7 Ul268
  • Dimension: D103mm.*H47mm

Smoke detector

SD-602

SD-604

SD-605

SD-606

www.nbdeling.com

WIRED PHOTOELECTRIC SMOKE DETECTOR

WIRED PHOTOELECTRIC SMOKE DETECTOR

  • Low standby current,Anti-RFI& anti-EMI
  • Operating voltage:DC:9V~35V(orders:DC40~60V)
  • Flashing led power indicator
  • Standby current 55uA
  • Alarm indication: red LED
  • Alarm current: 55mA@DC24V;25mA@DC12V
  • Reset: power off or auto reset
  • Alarm output: Remote led for 2 wires;Relay output for 4 wires
  • Sensitivity 0.13db/m( 0.05db/m)
  • Standard ED54-7 UL268
  • Dimension D103mm.*H53mm

WIRED PHOTOELECTRIC SMOKE DETECTOR

WIRED PHOTOELECTRIC SMOKE DETECTOR

  • Low standby current, Anti-RFI& anti-EMI
  • Operating voltage DC 9V~35V
  • Flashing led power indicator
  • Alarm indication: red LED
  • Standby current 55uA,
  • Alarm current: 55mA@DC24V;25mA@DC12V
  • Reset: power off or auto reset
  • Alarm output: Remote led for 2 wires;Relay output for 4 wires
  • Alarm point:ate-of-rise
  • Alarm temperature rising rate 8 /M;
  • Fixed temperature alarm: 57 (135 )
  • Standard ED54-7 Ul268
  • Dimension D101mm.*H55mm

  • Low standby current, Anti-RFI& anti-EMI
  • Operating voltage DC 9V~35V
  • Flashing led power indicator
  • Alarm indication: red LED
  • Standby current 55uA,
  • Alarm current: 55mA@DC24V;25mA@DC12V
  • Reset: power off or auto reset
  • Alarm output: Remote led for 2 wires;Relay output for 4 wires
  • Alarm point:ate-of-rise
  • Alarm temperature rising rate 8 /M;
  • Fixed temperature alarm: 57 (135 )
  • Standard ED54-7 Ul268
  • Dimension D101mm.*H49mm

  • Low standby current, Anti-RFI& anti-EMI
  • Operating voltage DC 9V~35V
  • Flashing led power indicator
  • Alarm indication: red LED
  • Standby current 55uA,
  • Alarm current: 55mA@DC24V;25mA@DC12V
  • Reset: power off or auto reset
  • Alarm output: Remote led for 2 wires;Relay output for 4 wires
  • Alarm point:ate-of-rise
  • Alarm temperature rising rate 8 /M;
  • Fixed temperature alarm: 57 (135 )
  • Standard ED54-7 Ul268
  • Dimension D101mm.*H49mm

Heat detector

www.nbdeling.com

WIRED HEAT DETECTOR

WIRED HEAT DETECTOR

WIRED HEAT DETECTOR

WIRED HEAT DETECTOR

HD-503

HD-504

SD-605H

HD-506

  • Low standby current, Anti-RFI& anti-EMI
  • Operating voltage DC 9V~35V
  • Flashing led power indicator
  • Alarm indication: red LED
  • Standby current 55uA,
  • Alarm current: 55mA@DC24V;25mA@DC12V
  • Reset: power off or auto reset
  • Alarm output: Remote led for 2 wires;Relay output for 4 wires
  • Alarm point:ate-of-rise
  • Alarm temperature rising rate 8 /M;
  • Fixed temperature alarm: 57 (135 )
  • Standard ED54-7 Ul268
  • Dimension D101mm.*H55mm

  • Base material: 6"/8"/10"
  • Plastic white base size:
  • Operating voltage: DC24V/220V
  • Working current: 25mA
  • Audio alarm: 95db
  • Driving way: motor

  • Base material: 6"/8"/10"
  • Plastic white base size:
  • Operating voltage: DC24V/220V
  • Working current: 25mA
  • Audio alarm: 95db
  • Driving way: motor

  • Rated voltage:12V/24VDC
  • Rated current:80mA 100mA
  • Flash intensity 1.2ws,flash period 1.5s
  • Audio alarm 105 db
  • Temperature range:-10 +55
  • Humidity range: 95%
  • The life-span of flash lamp's frequent;flashing: 40000 times
  • The Xenon light is imported with high
  • volume flash
  • Size:160L X 117W X 53H mm

Fire bell

www.nbdeling.com

FIRE ALARM BELL

FIRE ALARM BELL

FIRE STROBE SOUNDER

FIRE STROBE SOUNDER

HD-504

  • Rated voltage:12V/24VDC
  • Rated current:80mA 100mA
  • Flash intensity 1.2ws,flash period 1.5s
  • Audio alarm 105 db
  • Temperature range:-10 +55
  • Humidity range: 95%
  • The life-span of flash lamp's frequent;flashing: 40000 times
  • The Xenon light is imported with high
  • volume flash
  • Size:134L X 115W X 48H mm

FA-400

FA-401

FA-410

FA-411

  • Rated voltage:12V/24VDC
  • Rated current:80mA 100mA
  • Flash intensity 1.2ws,flash period 1.5s
  • Audio alarm 105 db
  • Temperature range:-10 +55
  • Humidity range: 95%
  • The life-span of flash lamp's frequent;flashing: 40000 times
  • The Xenon light is imported with high volume flash
  • Size:139L x 114W x 60H mm

  • Rated voltage:24VDC
  • Rated current:80mA 100mA
  • Flash intensity 1.2ws, flash period 1.5s
  • Temperature range:-10 +55
  • Humidity range: 95%
  • The life-span of flash lamp's frequent
  • Flashing: 40000 times
  • The Xenon light is imported with high volume flash
  • Size:179L x 139W x 65Hmm

  • Voltage: 24VDC (50mA)/ 12VDC (100mA)
  • Sound: 100db +/- 5dB (at 24VDC, 1 meter)
  • Tone: harmonic bell sound or sweep tone or siren sound
  • Operating current (at 24VDC):22mA (bell only)
  • Material: polycarbonate (UL94V-2)
  • Color: red
  • Size:82L x 82W x 30Hmm

Fire siren

www.nbdeling.com

FIRE STROBE SOUNDER

FIRE STROBE LIGHT

FIRE STROBE SOUNDER

FIRE STROBE SOUNDER

  • Voltage: 24VDC (50mA)/ 12VDC (100mA)
  • Sound: 100db +/- 5dB (at 24VDC, 1 meter)
  • Strobe: 8,000mcd, six super bright led
  • Tone: harmonic bell sound or sweep tone or siren sound
  • Operating current (at 24VDC):22mA (bell only);
  • 50mA (with strobe)
  • Material: polycarbonate (UL94V-2)
  • Color: red
  • Size:82L x 82W x 52Hmm

FA-412

FA-413

FA-416

FA-417

  • The push button panel is plastic material can't reset.
  • Operation voltage:24VDC
  • Max. Current: 1A at 24VDC
  • Contact resistance: 0.2ohm
  • Working conditions:
  • Temp. range: -10 +50
  • Max. relative humidity: 93RH 2%
  • Size:87x87x51mm
  • Color: red, yellow, green

  • The push button panel is plastic material can reset.
  • Operation voltage:24VDC
  • Max. Current: 1A at 24VDC
  • Contact resistance: 0.2ohm
  • Working conditions:
  • Temp. range: -10 +50
  • Max. relative humidity: 93RH 2%
  • Size:87x87x51mm
  • Color: red, yellow, green

  • Glass push button panel, can't reset,with LED indicator
  • LED indicator, green for working, red for alarm
  • Operation voltage:24VDC
  • Max. Current: 1A at 24VDC
  • Contact resistance: 0.2ohm
  • Working conditions:
  • Temp. range: -10 +50
  • Max. relative humidity: 93RH 2%
  • Size:87x87x51mm
  • Color: red, yellow, green

Fire call point

www.nbdeling.com

FIRE MANUL CALL POINT

RESETTABLE FIRE CALL POINT

FIRE CALL POINT WITH LED INDICATOR

FIRE CALL POINT WITH LED INDICATOR

  • Glass push button panel, can't reset,with LED indicator
  • LED indicator, green for working, red for alarm
  • Operation voltage:24VDC
  • Max. Current: 1A at 24VDC
  • Contact resistance: 0.2ohm
  • Working conditions:
  • Temp. range: -10 +50
  • Max. relative humidity: 93RH 2%
  • Size:87x87x51mm
  • Color: red, yellow, green

FA-501

FA-502

FA-504

FA-505

  • The push button panel is plastic material can reset.
  • Operation voltage:9-28VDC
  • Alarm. Current: <45mA 
  • Contact resistance: 0.2ohm
  • Working conditions:
  • Temp. range: -10 +50
  • Max. relative humidity: 93RH 2%
  • Size:140*104*45mm
  • Color: red 

  • The push button panel is plastic material can reset.
  • Operation voltage:24VDC
  • Max. Current: 1A at 24VDC
  • Contact resistance: 0.2ohm
  • Working conditions:
  • Temp. range: -10 +50
  • Max. relative humidity: 93RH 2%
  • Size:125*95*80mm
  • Color: red, yellow, green

  • The push button panel is plastic material can reset.
  • Operation voltage:24VDC
  • Max. Current: 1A at 24VDC
  • Contact resistance: 0.2ohm
  • Working conditions:
  • Temp. range: -10 +50
  • Max. relative humidity: 93RH 2%
  • Size:87x87x51mm
  • Color: red, yellow, green

Fire call point

www.nbdeling.com

FIRE MANUL CALL POINT

WATER PROFF COVER WITH  CALL POINT

FIRE CALL POINT WITH LED INDICATOR

WATER PROOF MANUL CALL POINT

  • The push button panel is plastic material can reset.,with LED indicator
  • LED indicator,red for alarm
  • Operation voltage:24VDC
  • Max. Current: 1A at 24VDC
  • Contact resistance: 0.2ohm
  • Working conditions:
  • Temp. range: -10 +50
  • Max. relative humidity: 93RH 2%
  • Size:87x87x51mm
  • Color: red, yellow, green

FA-507

FA-512

FA-511L

FA-513

  • Operation voltage:DC9V/AC 220V optional
  • Current static current <10uA
  • Alarm current <12mA
  • Audio alarm: 85dB/3m
  • Temp. Range: 10 60
  • Humidity range: 95 RH(40 2
  • 9V battery power source power supply
  • Low battery warning
  • Protection area: 6 m high,60
  • Size 140Dx41H mm

  • Operation voltage DC9V/AC 220V optional
  • Current static current <10uA
  • Alarm current <12mA;
  • Audio alarm: 85dB/3m
  • Temp. Range: 10 60
  • Humidity range: 95 RH(40 2
  • 9V battery power source power supply
  • Low battery warning
  • Protection area: 6 m high,60
  • Size 140Dx41H mm

  • Operation voltage:DC9V or AC 220V optional
  • Current static current <10uA
  • Alarm current <12mA
  • Audio alarm: 85dB/3m
  • Interconnected each other
  • Temp. Range: 10 60
  • Humidity range: 95 RH(40 2
  • Low battery warning
  • Protection area: 6 m high,60
  • Size 140Dx41H mm

Standalone smoke detector

www.nbdeling.com

STANDALONE PHOTOELECTRIC SMOKE DETECTOR

STANDALONE PHOTOELECTRIC SMOKE DETECTOR

STANDALONE PHOTOELECTRIC SMOKEDETECTOR

INTERCONNECTED/STANDALONE PHOTOELECTRIC SMOKE DETECTOR

  • Operation voltage DC9V/AC 220V optional
  • Current static current <10uA
  • Alarm current <12mA;
  • Audio alarm: 85dB/3m
  • Temp. Range: 10 60
  • Humidity range: 95 RH(40 2
  • 9V battery power source power supply
  • Low battery warning
  • Protection area: 6 m high,60
  • Size 140Dx41H mm

SD-423

SD-424

SD-425

SD-425B

  • Operation voltage:DC9V or AC 220V optional
  • Current static current <10uA
  • Alarm current <12mA
  • Audio alarm: 85dB/3m
  • Heat sensor: 57 for alarm point
  • Interconnected each other
  • The 9V battery power source power supply
  • Low battery warning
  • Protection area: 6 m high , 60
  • Size 140Dx41H mm

  • Operation voltage:DC9V
  • Current:static current <10µA,
  • Alarm current≤10mA;
  • Alarm point:57℃
  • Audio alarm: ≥85db/m
  • Temp. Range: -10℃~+60℃
  • Humidity range: ≤95%RH(40℃±2℃)
  • Low battery warning
  • Protection area: 6 m high , 60 ㎡
  • Size: 113φx38H mm

  • Operating voltage: DC5V with 85-265V Power adapter
  • Back-up battery can work for 8 hours when power is off
  • Alarm level: 10% ±5% LEL
  • Sound Level:85dB/1m
  • Auto reset after alarm
  • Automatic detection of fault
  • MCU processing adopted
  • Induced gas-nature gas/LPG
  • Working with electromagnetic valve or manipulator
  • Malfunction auto-check indicator
  • Independent: Sound&Flash alarm
  • Size:Φ94*35mm

Gas detector

www.nbdeling.com

GAS LEAKING DETECTOR

GAS LEAKING DETECTOR

  • High reliability sensor
  • Auto reset after alarm
  • MCU processing adopted
  • Auto detect sensor failure
  • Induced gas-natural gas/LPG
  • Work with electro valve & mainpulator
  • Operating voltage: AC85~265V
  • Static current: 90mA ;Alarm current: 100mA
  • Rating power: 3W ( AC 220V supply )
  • Warm-up time: 180S
  • Alarm level: 10%LEL,Sound level: 85dB/1m
  • Alarm output: relay output sound& flash alarm
  • Size:115x72x45mm

INTERCONNECTED PHOTOELECTRIC SMOKE& HEAT DETECTOR

SD-425H

STANDALONE HEAT DETECTOR

HD-505

SD-702

GD-706

NBDELIN

Tel: +86 574 8816 7175
Web:http://www.nbdeling.com
Add: No.8,Sanjiang Road,Wuxiang Industry Zone,Yinzhou District,Ningbo,China

Ningbo Deling Electron Technology Company Limited

Copyright © 2024 陕西妙网网络科技有限责任公司 All Rights Reserved

增值电信业务经营许可证:陕B2-20210327 | 陕ICP备13005001号 陕公网安备 61102302611033号